WELDING CABLES

Standards :

Generally conforms To Based On CENELEC Hd 22-6-31, VDE 0282, IEC 245-6, BS 6899, IS 6830/84

Conductor :

High conductivity, bare annealed copper flexible conductor EC copper class 5 and 6 generally conforms to IEC 60228, DIN VDE 0281

Insulation :

double Insulated flexible Nitrile Rubber (NBR) insulated

Colour :

Orange / Black jacket

Standard Packing :

coils 100, 200, 300, 500 m

Application :

Designed for the secondary (high current) connection to automatic or hand - held metal arc welding electrodes. it is suitables for flexible use under rugged condiction, on assembly lines and conveyor systems, in machine tool automatically operated line and spot welding machines.

Voltage Drop :

When total cable lenghts in excess of 15 mtrs, are involved it may be necessary to use cables of larger cross section to ensure that the voltage drop is not excessive and welding currents are maintained at adequate levels.

Silent Features :

  • Ultra high perfomance flexible welding lead, double insulated for longer life and added safety
  • Better flame retardant properties
  • Outstanding toughness & durability
  • High resistance to cut, tears & abrasion
  • Resistance to oil, solvents and chemicals
  • Excellent ozone and weather resistant

Technical Data :

Fixed Installation

Nominal Voltage

Test Voltage

Insulation Resistance

Min. bending radius

Current Rating :

The maximum current ratings of flexible welding cables for different duty cycles on an ambient air temperature of 25c and a maximum conductor temperature of 908 the percentage duty cycle for various processes and application are as follows :

Cable Rating Table
Cable Size
sqmm
Nominal thickness
mm
Overall Cable Diameter
mm
Max Conductor Resistance At 20°C Current Rating Welding Application Non-welding Application
amp
Core Sheath Lower Limit Upper Limit 100% 85% 60% 30% 20%
sqmm mm mm mm mm Ω/km amp amp amp amp amp amp
10.0 1.2 1.8 7.8 10.0 1.910 105 115 135 190 235 110
16.0 1.2 1.9 9.0 11.5 1.210 135 145 175 245 302 138
25.0 1.4 2.0 10.0 13.0 0.780 180 195 230 330 402 187
35.0 1.4 2.2 11.5 14.5 0.554 225 245 290 410 503 233
50.0 1.6 2.4 13.0 17.0 0.386 285 310 370 520 637 295
70.0 1.6 2.6 15.0 19.0 0.272 355 385 460 650 794 372
95.0 1.8 2.8 21.5 24.0 0.206 430 470 560 790 961 449
120.0 1.8 3.0 24.0 24.0 0.161 500 540 650 910 1118 523
  • Automobile Welding: upto 100%
  • Semi Automobile Welding: 30% to 85%
  • Manual Welding: 0% to 60%
  • Very Intermitted Or Occasional Welding: upto 20%
Cable Rating Table
Rating factors for variation in ambient temperature
Ambient Temperature °C 20°C 25°C 30°C 35°C 40°C 45°C 50°C 55°C 60°C 65°C
Rating Factor 1.04 1.04 1.04 1.04 1.04 1.04 1.04 0.69 0.64 0.57